TM 5-3895-373-34
2.63
REPLACE AND ADJUST AUGER/CONVEYOR DRIVE CHAIN - Continued.
A.
REMOVE - Continued.
4.
REMOVE TOP CHAIN COVER PLATE FROM
AUGER/CONVEYOR DRIVE CHAIN HOUSING.
NOTE
Hydraulic hoses routed over the top of top
chain
cover
plate
may
need
to
be
repositioned temporarily to gain access to
hex head cap screws and to allow removal of
top chain cover plate.
a.
Remove hex head cap screws (21) and flat
washers (22) from top chain cover plate
(23).
b.
Remove
top
chain
cover
plate
from
auger/conveyor drive chain housing.
5.
POSITION
OFFSET
CHAIN
LINK
TO
DISCONNECT
AUGER/CONVEYOR
DRIVE
CHAIN.
Do not allow hands or loose clothing into
auger/conveyor drive chain housing while
auger/conveyor is rotating. Keep hands and
loose clothing clear of auger/conveyor drive
chain housing when drive chain is moving.
Severe injury to personnel can result from
hands or loose clothing being caught in
sprocket wheels when drive chain is moving.
a.
With the help of another person, operate
auger/conveyors at very low speed to locate
master chain link (24) on auger/conveyor
drive chain (25) per TM 5-3895-373-10.
b.
Stop auger/conveyors when master chain
link (24) is visible in auger/conveyor drive
chain housing (5).
GO TO NEXT PAGE
2-864