TM 5-3895-373-34
2.55
REPLACE VALVE PANEL CONTROL VALVES AND FLOW DIVIDERS - Continued.
C.
INSTALL - Continued.
Hydraulic fitting sealant can cause eye
damage or skin irritation. Wash after
skin
contact.
Wear
safety
goggles/glasses when using. Avoid
contact with eyes or skin. If sealant
contacts eyes, flush eyes with water and
get immediate medical attention.
l.
Apply hydraulic fitting sealant to exposed threads
of elbows (164 and 168), swivel elbow (166), and
straight adapter (170).
m.
Connect hose (167) to elbow (168). Tighten
hose.
n.
Connect tube (165) to swivel elbow (166).
Tighten tube.
o.
Connect tube (163) to elbow (164). Tighten
tube.
p.
Connect tube (169) to straight adapter (170).
Tighten tube. Ensure opposite end of tube is
tightened.
q.
Apply electrical insulating compound to male
ends of stack valve electrical connectors (159
and 160). Plug stack valve electrical connectors
into harness electrical connectors (161 and 162).
r.
Install tie wraps to electrical harnesses as
needed.
GO TO NEXT PAGE
2-766