TM 5-3895-373-34A.REMOVE - Continued.j.While holding hex head cap screw (187) with awrench, remove hex nut (188), lockwasher(189), and flat washer (190) from underneathvalve panel. Discard lockwasher.k.Remove hex head cap screw (187), ground wirelead (191), flat washer (192), and ground wirelead (193).l.While holding hex head cap screws (194) with awrench, remove hex nuts (195), lockwashers(196), and flat washers (197) from underneathvalve panel. Discard lockwashers.m.Remove hex head cap screws (194) and flatwashers (198). Remove stack valve (158) frompaving machine.n.If replacing stack valve (158), remove the wiringharnesses per paragraph 2.44 and reinstall onreplacement stack valve.B.CLEAN.1.CLEAN ALL FASTENERS WITH THREADLOCKING COMPOUND SOLVENT.Thread locking compound solvent cancause eye damage. Wear safetygoggles/glasseswhen using. Avoidcontact with eyes. If solvent contactseyes, flush eyes with water and getimmediate medical attention.a.Clean all fasteners with thread lockingcompound solvent.b.Wipe fasteners dry with a cleaning cloth.GO TO NEXT PAGE2-761