TM 5-3895-373-34
A.
REMOVE - Continued.
j.
While holding hex head cap screw (187) with a
wrench, remove hex nut (188), lockwasher
(189), and flat washer (190) from underneath
valve panel. Discard lockwasher.
k.
Remove hex head cap screw (187), ground wire
lead (191), flat washer (192), and ground wire
lead (193).
l.
While holding hex head cap screws (194) with a
wrench, remove hex nuts (195), lockwashers
(196), and flat washers (197) from underneath
valve panel. Discard lockwashers.
m.
Remove hex head cap screws (194) and flat
washers (198). Remove stack valve (158) from
paving machine.
n.
If replacing stack valve (158), remove the wiring
harnesses per paragraph 2.44 and reinstall on
replacement stack valve.
B.
CLEAN.
1.
CLEAN
ALL
FASTENERS
WITH
THREAD
LOCKING COMPOUND SOLVENT.
Thread locking compound solvent can
cause
eye
damage.
Wear
safety
goggles/glasses
when
using.
Avoid
contact with eyes. If solvent contacts
eyes, flush eyes with water and get
immediate medical attention.
a.
Clean
all
fasteners
with
thread
locking
compound solvent.
b.
Wipe fasteners dry with a cleaning cloth.
GO TO NEXT PAGE
2-761