TM 5-3895-373-34
2.55
REPLACE VALVE PANEL CONTROL VALVES AND FLOW DIVIDERS - Continued.
C.
INSTALL - Continued.
Hydraulic fitting sealant can cause eye
damage or skin irritation. Wash after
skin contact. Wear safety goggles/
glasses when using. Avoid contact with
eyes or skin. If sealant contacts eyes,
flush eyes with water and get immediate
medical attention.
h.
Apply hydraulic fitting sealant to exposed threads
of elbows (183, 184, 185, and 186).
NOTE
Make sure that hydraulic hoses are
connected to the correct elbows.
i.
Connect hoses (179, 180, 181, and 182) to
elbows (183, 184, 185, and 186). Hoses
connect to stack valve ports as follows: (179) to
A5, (180) to A4, (181) to A2, and (182) to A1.
GO TO NEXT PAGE
2-764