TM 5-3895-373-34
2.55.
REPLACE VALVE PANEL CONTROL VALVES AND FLOW DIVIDERS - Continued
A.
REMOVE - Continued.
6.
REMOVE TUBES AND HOSES FROM LEFT
AUGER/CONVEYOR SPEED CONTROL VALVE.
Hydraulic
oil
can
be
moderately
flammable and can be an irritant to
the
skin,
eyes,
and
respiratory
system. Avoid prolonged exposure.
Eye protection and rubber gloves
must be worn when working with
hydraulic oil.
Thoroughly clean hoses and fittings
before disconnecting. Always plug or
cap
off
disconnected
fittings
to
prevent intrusion of contaminants.
Failure to properly clean and cap off
connectors may result in system
contamination
and
equipment
damage.
NOTE
The auger/conveyor speed control
valve only needs to be removed when
removing the auger/conveyor control
valve. Remove left speed control
valve if removing left control valve.
Remove right speed control valve if
removing right control valve.
a.
Wipe all dirt and dust from fittings with cleaning
cloths.
b.
Place a machinery wiping towel beneath left
auger/conveyor speed control valve (83).
NOTE
It may be necessary to plug and cap
fittings after auger/conveyor speed
control valve removal, step A.7.
c.
Tag and disconnect tube (84) from straight
adapter (85). Plug tube and cap straight
adapter.
d.
Tag and disconnect tubes (86 and 87) from
elbow (88) and straight adapter (89). Plug
tubes and cap elbow and straight adapter.
e.
Tag and disconnect hose (90) from elbow (91).
Plug hose and cap elbow.
f.
Tag and disconnect hose (92) from tube
reducer (93). Plug hose and cap tube reducer.
GO TO NEXT PAGE
2-746