TM 5-3895-373-34
2.55.
REPLACE VALVE PANEL CONTROL VALVES AND FLOW DIVIDERS - Continued
A.
REMOVE - Continued.
8.
REMOVE TOW POINT FLOW DIVIDER AND TOW
POINT FLOW CONTROL VALVE.
Hydraulic
oil
can
be
moderately
flammable and can be an irritant to
the skin, eyes and respiratory system.
Avoid prolonged exposure. Eye
protection and rubber gloves must be
worn when working with hydraulic
oil.
Thoroughly clean hoses and fittings
before disconnecting. Always plug or
cap
off
disconnected
fittings
to
prevent intrusion of contaminants.
Failure to properly clean and cap off
connectors may result in system
contamination
and
equipment
damage.
a.
Wipe all dirt and dust from fittings with cleaning
cloths.
NOTE
It may be necessary to remove
hydraulic tubes and plug and cap
fittings after removal of tow point
flow divider and tow point flow
control valve, step f.
b.
Tag and disconnect swivel tee (50) from
straight adapter (100). Plug swivel tee and cap
straight adapter.
c.
Tag and disconnect tubes (101 and 102) from
elbows (103 and 104). Plug tubes and cap
elbows.
d.
Tag and disconnect tube (49) from straight
adapter (51).