TM 5-3895-373-34
2.48
REPAIR AUGER/CONVEYOR SPEED CONTROL VALVE - Continued.
B.
CLEAN - Continued.
Compressed air used for cleaning
purposes will not exceed 30 psi (207
kPa). Use only with effective chip
guarding
and
personal
protective
equipment (goggles/face shield and
gloves). Failure to take proper
precautions may result in severe
injury or loss of vision.
c.
Use
30
psi
(207
kPa)
maximum
compressed air to remove any foreign
matter from valve body, threaded surfaces,
bores and seal grooves. Dry all parts with a
clean, lint-free cloth.
2.
CLEAN HEX HEAD CAP SCREWS AND SET
SCREWS.
Thread locking compound solvent
can cause eye damage. Wear safety
goggles/glasses when using. Avoid
contact with eyes. If solvent contacts
eyes, flush eyes with water and get
immediate medical attention.
a.
Clean threads of hex head cap screws and
set screws with thread locking compound
solvent.
b.
Dry with a clean, cleaning cloth.
C.
INSPECT.
1.
INSPECT
VALVE
BODY,
SPRINGS,
AND
SPOOL FOR STRIPPED THREADS, WEAR,
SCRATCHES,
DENTS,
AND
FOREIGN
MATERIAL, AND SPRINGS FOR DAMAGE
AND WEAR.
GO TO NEXT PAGE
2-654