TM 5-3895-373-34
2.38.
REPLACE/REPAIR TRACK TENSIONING RELIEF VALVE AND UNLOADING VALVE - Continued
F.
INSTALL - Continued.
3.
CONNECT HYDRAULIC LINES AND HOSES.
Hydraulic fitting sealant can cause eye
damage or skin irritation. Wash after
skin
contact.
Wear
safety
goggles/glasses when using. Avoid
contact with eyes or skin. If sealant
contacts eyes, flush eyes with water and
get immediate medical attention.
a.
Apply hydraulic fitting sealant to the exposed
threaded ends of tee (4), straight adapters (8
and 10), and elbows (12 and 5).
b.
Connect hose (7) to straight adapter (8) on
track tensioning relief valve (1) and tee (4) on
track tensioning unloading valve (2).
c.
Connect tube (9) to straight adapter (10) and
stack valve straight adapter.
d.
Connect hose (11) to elbow (12).
e.
Connect tube (3) to elbow (5) on return
manifold (6) and tee (4) on track tensioning
unloading valve (2).
NOTE
FOLLOW-ON-TASKS:
Close center top right access door per TM 5-3895-373-10.
Close right access door per TM 5-3895-373-10.
END OF TASK
2-534