TM 5-3895-373-34
2.27
REPLACE/REPAIR HIGH SPEED SHIFT VALVE - Continued.
F.
INSTALL - Continued.
Electrical insulating varnish fumes
can be harmful if inhaled. Use only in
a
well
ventilated
area.
Avoid
prolonged exposure to fumes. If
personnel become dizzy or drowsy
during use, get immediate medical
attention.
e.
Apply
electrical
insulating
varnish
to
exposed surfaces of bolt (9), sleeve spacer
(10), and ground wire (11).
2.
INSTALL
ELECTRICAL
AND
HYDRAULIC
CONNECTIONS.
Hydraulic fitting sealant can cause
eye damage or skin irritation. Wash
after skin contact. Wear safety
goggles/glasses when using. Avoid
contact with eyes or skin. If sealant
contacts eyes, flush eyes with water
and get immediate medical attention.
a.
Apply hydraulic fitting sealant to threads of
straight adapters (33) and tee (34).
b.
Connect return manifold hose (8), brake
hose (7), charge pump hose (6), and track
drive hoses (5 and 4). Tighten hose.
c.
Apply electrical insulating compound to
male end of high speed shift valve electrical
connector (1).
d.
Connect high speed shift valve electrical
connector
(1)
to
harness
electrical
connector (2).
NOTE
FOLLOW-ON-TASK: Close center top left access door per TM 5-3895-373-10.
END OF TASK
2-372