TM 5-3895-373-34
D.
ASSEMBLE - Continued.
2.
INSTALL VALVES, PREFORMED PACKING,
FILTER SCREEN, AND FILTER COVER ON
COVER.
a.
Use contact point dresser and remove old
staking flanges from valve seats (12) on
inside of cover (3).
Compressed air used for cleaning
purposes will not exceed 30 psi (207
kPa). Use only with effective chip
guarding
and
personal
protective
equipment (goggles/face shield and
gloves.). Failure to take proper
precautions may result in severe
injury or loss of vision.
b.
Rinse cover in warm, soapy water and use
compressed air to remove metal particles
from filing. Dry cover with a clean, lint-free
cloth.
c.
Position gasket (11) and valve (10) on fuel
inlet to allow fuel to flow into fuel lift pump.
Install valve on inlet with a flat blade
screwdriver.
d.
Position gasket (11) and valve (10) on fuel
outlet to allow fuel to exit fuel lift pump.
Install valve on outlet with a flat blade
screwdriver.
e.
Use a small punch and punch six new
staking flanges on each valve to hold
valves in position.
f.
Install filter screen (9) into cover (3).
g.
Install preformed packing (8) into cover.
h.
Install hex head cap screw (5) through seal
washer (6).
i.
Install hex head cap screw through filter
cover (7) and into cover. Tighten cap
screw (5).
GO TO NEXT PAGE
2-295