TM 5-3895-373-20
B.
INSTALL - Continued.
4.
INSTALL ENGINE ACCESS COVER
AND MOUNTING HARDWARE.
a.
Install brackets (37) loosely with hex head
cap screws (36).
b.
Install engine access cover (35) with
socket head cap screws (34).
c.
Tighten hex head cap screws (36).
d.
Tighten socket head cap screws (34).
5.
INSTALL
OPERATOR
CONTROL
CONSOLE
GAUGE
PANEL
ACCESS
DOORS.
Adhesive is TOXIC and extremely
flammable. Keep away from heat,
sparks, and open flames. Use only in
well ventilated areas. Do not breathe
vapors or swallow and avoid contact
with eyes and skin. Failure to do so
may result in injury or death to
personnel.
If personnel become dizzy while
using adhesive, immediately get fresh
air and medical attention.
If personnel swallow adhesive, do not
induce vomiting and get immediate
medical
attention.
If
adhesive
contacts eyes, flush eyes with water
for 15 minutes. Get immediate
medical
attention.
If
adhesive
contacts skin, wash thoroughly with
soap and water.
a.
Apply adhesive to door seal (26).
b.
Install door seal (26) onto gauge panel
access door (25). Press firmly in place.
c.
Install gauge panel access door (25) and
secure with screws (24), washers (23),
and hex nuts (22). Tighten hex nuts.
GO TO NEXT PAGE