TM 5-3895-373-207.17.REPLACE DCA AND PRESSURE TRANSMITTERS - Continued.A.REMOVE.1.REMOVE DCA HOUSING COVER.a.Using flat head bit from screwdriver bit set,remove screws (1) and lift housing cover(2) from DCA housing.b.Remove machine screws (3), electricalcomponent cover (4), flat washers (5),and hex nuts (6) from DCA harnessconnector (7).c.Tag and disconnect wires 151 (8) and 322(9) from engine crank toggle switch (10).d.Tag and disconnect wires 314 (11) andwire 315 (12) from zero offset toggleswitch (13).NOTEToggle switch "ON" markings arepositioned toward front of housingcover (2).e.Remove hex nuts (14), lockwashers (15),engine crank toggle switch (10) and zerooffset toggle switch (13).GO TO NEXT PAGE7-118