TM 5-3895-373-20
7.16.
REPLACE HYDRAULIC OIL TEMPERATURE SENSOR - Continued.
B.
INSTALL.
Pipe sealant can cause eye damage
or skin irritation. Wash after skin
contact.
Wear
safety
goggles/glasses when using. Avoid
contact with eyes or skin. If sealant
contacts eyes, flush eyes with water
and get immediate medical attention.
1.
APPLY PIPE SEALANT TO THREADS
OF HYDRAULIC OIL TEMPERATURE
SENSOR (2).
2.
REMOVE PROTECTIVE CAP.
3.
INSTALL
HYDRAULIC
OIL
TEMPERATURE
SENSOR
(2)
INTO
STRAIGHT ADAPTER (4).
4.
INSTALL GAUGE PANEL HARNESS
RING TERMINAL (3)
ONTO
HYDRAULIC
OIL
TEMPERATURE
SENSOR (2). SECURE WITH KNURLED
NUT (1).
Electrical insulating varnish fumes
can be harmful if inhaled. Use only
in a well ventilated area. Avoid
prolonged exposure to fumes. If
personnel become dizzy or drowsy
during use, get immediate medical
attention.
5.
APPLY
ELECTRICAL
INSULATING
VARNISH TO GAUGE PANEL HARNESS
RING TERMINAL (3).
NOTE
FOLLOW-ON-TASK:
Close right access door per TM 5-3895-373-10.
END OF TASK
7-116