TM 5-3895-373-20
A.
CALIBRATE Continued.
h.
Digital multimeter should show and increasing
output of 93 to 97 mA as right control handle (7)
is moved away from center, neutral, position.
i.
If meter reading is less than 93 mA or greater
than 97 mA, using a jewelers screwdriver, adjust
right control handle (7) potentiometer (FMAX)
until reading between 93 mA and 97 mA is
obtained. To increase, turn adjustment screw
clockwise.
To
decrease
mA
reading,
turn
adjustment screw counterclockwise.
j.
Return right control handle (7) to the 0.75 in. (19
mm) position as in step d.
k.
Digital multimeter should read 6 to 8 mA.
1.
If meter reading is less than 6 mA or greater
than 8 mA, using a jewelers screwdriver, adjust
control handle threshold potentiometer (FT) on
right control handle (7). To increase, turn
adjustment screw clockwise. To decrease mA
reading,
turn
adjustment
screw
counterclockwise.
m.
Return right control handle (7) to the center,
neutral, position.
n.
Remove digital multimeter leads from right
control handle (7) electrical connector P34 (6)
and J34 (8) and connect the connectors.
GO TO NEXT PAGE
7-71