TM 5-3895-373-20A. CALIBRATE Continued.h.Digital multimeter should show and increasingoutput of 93 to 97 mA as right control handle (7)is moved away from center, neutral, position.i.If meter reading is less than 93 mA or greaterthan 97 mA, using a jeweler’s screwdriver, adjustright control handle (7) potentiometer (FMAX)until reading between 93 mA and 97 mA isobtained. To increase, turn adjustment screwclockwise. To decrease mA reading, turnadjustment screw counterclockwise.j.Return right control handle (7) to the 0.75 in. (19mm) position as in step d.k.Digital multimeter should read 6 to 8 mA.1.If meter reading is less than 6 mA or greaterthan 8 mA, using a jeweler’s screwdriver, adjustcontrol handle threshold potentiometer (FT) onright control handle (7). To increase, turnadjustment screw clockwise. To decrease mAreading, turn adjustment screwcounterclockwise.m.Return right control handle (7) to the center,neutral, position.n.Remove digital multimeter leads from rightcontrol handle (7) electrical connector P34 (6)and J34 (8) and connect the connectors.GO TO NEXT PAGE7-71