TM 5-3895-373-207.8. ADJUST/CALIBRATE CONTROL HANDLES.This task covers: a. Calibrate b. AdjustINITIAL SETUP:Tools:References:General mechanic’s automotive tool kitTM 5-3895-373-10(Item 54, Appendix E)Combination square (Item 48, Appendix E)Equipment Condition:Digital multimeter (Item 25, Appendix E)Gauge panel left access door openJeweler’s screwdriver set (Item 38, Appendix E) per TM 5-3895-373-10.Gauge panel right access door openMaterials/Parts:per TM 5-3895-373-10.Electrical insulating compound (Item 11, Appendix C)A. CALIBRATE.NOTECalibration will adjust control handles toa starting point for the actual trackingadjustment performed in step B.1. CALIBRATE LEFT CONTROL HANDLEFORWARD THRESHOLD AND GAIN.a.Remove button head cap screws (1) and coverplate (2) from operator control console.GO TO NEXT PAGE7-67