TM 5-3895-373-20B. INSTALL Continued.2. CONNECT ELECTRICAL CONNECTORS ANDINSTALL ELECTRICAL CONTACTS AND RINGTERMINALS ONTO GAUGE PANELCOMPONENTS.Electrical insulating varnish fumes can be harmful ifinhaled. Use only in a well ventilated area. Avoidprolonged exposure to fumes. If personnel become dizzyor drowsy during use, get immediate medical attention.a.Install ring terminals (14) onto high temperaturemanual override button. Use a jeweler’sscrewdriver set to install lockwashers (13) andscrews (12). Apply electrical insulating varnish toring terminals.b.Install ring terminals (11) onto throttle controlswitch. Use a jeweler’s screwdriver set to installlockwashers (10) and terminal screws (9). Applyelectrical insulating varnish to ring terminals.c.Apply electrical insulating compound to ignitionswitch terminals. Install harness lug terminals (8)onto ignition switch terminals.d.Apply electrical insulating compound to electricalconnectors (7 and 6). Connect electricalconnectors to control handle electricalconnectors.e.Apply electrical insulating compound to terminalsof gauges. Install terminal plugs (5) into gauges.f.Apply electrical insulating compound to terminalplugs of indicator lights. Install harnessconnectors (4) to indicator lights.g.Install ring terminals (3) onto switches. Use ajeweler’s screwdriver set to install lockwashers(2) and terminal screws (1). Apply electricalinsulating varnish to ring terminals.GO TO NEXT PAGE7-5