TM 5-3895-373-20
D.
INSTALL - Continued.
f.
Install bulkhead adapter (22) and self-
locking hex nut (21). Tighten nut.
g.
Install and hand tighten air cleaner service
indicator knob (19).
WARNING
Hydraulic fitting sealant can cause
eye damage or skin irritation. Wash
after skin contact. Wear safety
goggles/glasses when using. Avoid
contact with eyes or skin. If sealant
contacts eyes, flush eyes with water
and get immediate medical attention.
h.
Apply hydraulic fitting sealant to exposed
threads of installed bulkhead adapter (22).
Install and tighten hose (20).
i.
Move hydraulic return filter (18) back to
mounting installation.
j.
Install lockwashers (17) onto bolts (16).
WARNING
Thread locking compound can cause
eye damage or skin irritation. Wash
after skin contact. Wear safety
goggles/glasses when using. Avoid
contact with eyes. If compound
contacts eyes, flush with water and
get immediate medical attention.
k.
Apply thread locking compound to threads
of bolts (16).
l.
Install bolts (16). Tighten to 14 lb-ft (19
N.m).
GO TO NEXT PAGE