TM 5-3895-373-20
4.3. REPLACE/REPAIR AIR INTAKE COMPONENTS - Continued.
D.
INSTALL - Continued.
3.
INSTALL AIR PRESSURE TRANSMITTER AND
AIR CLEANER SERVICE INDICATOR KNOB.
WARNING
Pipe sealant can cause eye damage
or skin irritation. Wash after skin
contact. Wear safety goggles/glasses
when using. Avoid contact with eyes
or skin. If sealant contacts eyes,
flush
eyes
with
water
and
get
immediate medical attention.
a.
Apply pipe sealant to male pipe threads of
tee (26), pipe reducer (25), and air
pressure transmitter (23).
b.
Install and tighten tee (26) into pressure
sense tube (27). Exposed male threads of
tee should point downward as shown in
illustration.
c.
Install pipe reducer (25) and air pressure
transmitter (23) into female thread end of
tee (26). Tighten pipe reducer and
pressure transmitter.
d.
Apply electrical insulating compound to
male connector of air pressure transmitter
(23). Plug pressure transmitter connector
into harness connector (24).
WARNING
Hydraulic fitting sealant can cause
eye damage or skin irritation. Wash
after skin contact. Wear safety
goggles/glasses when using. Avoid
contact with eyes or skin. If sealant
contacts eyes, flush eyes with water
and get immediate medical attention.
e.
Apply hydraulic fitting sealant to exposed
threads of tee (26). Install and tighten
hose (20).
GO TO NEXT PAGE
4-16