TM 5-3895-373-20
B.
CLEAN.
WARNING
Cleaning solvent, P-D-680, is TOXIC
and flammable. Wear protective
goggles and gloves. Use only in a
well ventilated area. Avoid contact
with skin, eyes, and clothes, and do
not breathe vapors. Keep away from
heat or flame. Never smoke when
using solvent; the flashpoint for
Type m cleaning solvent is 200°F
(93,3°C). Failure to do so may result
in injury or death to personnel.
If personnel become dizzy while
using cleaning solvent, immediately
get fresh air and medical help. If
solvent contacts skin or clothes,
flush with cold water. If solvent
contacts eyes, flush eyes with water
and get immediate medical attention.
1.
CLEAN ALL METAL PARTS WITH CLEANING
SOLVENT.
2.
SCRUB OFF HARD DEPOSITS WITH WIRE
SCRATCH BRUSH. WIPE DRY WITH
CLEANING CLOTH.
C.
ASSEMBLE.
1.
INSTALL STRIKEOFF PLATE.
NOTE
Install strikeoff plate with offset of
slots as noted during removal.
a.
Install spacer bar (11) and strikeoff plate
(10) onto screed extension strikeoff (12).
b.
Install flat washers (9) and self-locking
nuts (8). Tighten self-locking nuts to 90 lb-
ft (122 Nm).
2.
INSTALL STRIKEOFF SUPPORT.
a.
Install strikeoff support (7) and secure with
hex head cap screw (5), flat washers (6),
and self-locking nut (4). Tighten self-
locking nut.
b.
Install hex head cap screws (2), flat
washers (3), and self-locking nuts (1).
Tighten self-locking nuts.
NOTE
FOLLOW-ON-TASK:
Strikeoff extension assembly installed per
TM 5-3895-373-10.
END OF TASK
15-151/(15-152 blank)