TM 5-3895-373-20B.CLEAN.WARNINGCleaning solvent, P-D-680, is TOXICand flammable. Wear protectivegoggles and gloves. Use only in awell ventilated area. Avoid contactwith skin, eyes, and clothes, and donot breathe vapors. Keep away fromheat or flame. Never smoke whenusing solvent; the flashpoint forType m cleaning solvent is 200°F(93,3°C). Failure to do so may resultin injury or death to personnel.If personnel become dizzy whileusing cleaning solvent, immediatelyget fresh air and medical help. Ifsolvent contacts skin or clothes,flush with cold water. If solventcontacts eyes, flush eyes with waterand get immediate medical attention.1.CLEAN ALL METAL PARTS WITH CLEANINGSOLVENT.2.SCRUB OFF HARD DEPOSITS WITH WIRESCRATCH BRUSH. WIPE DRY WITHCLEANING CLOTH.C.ASSEMBLE.1.INSTALL STRIKEOFF PLATE.NOTEInstall strikeoff plate with offset ofslots as noted during removal.a.Install spacer bar (11) and strikeoff plate(10) onto screed extension strikeoff (12).b.Install flat washers (9) and self-lockingnuts (8). Tighten self-locking nuts to 90 lb-ft (122 N•m).2.INSTALL STRIKEOFF SUPPORT.a.Install strikeoff support (7) and secure withhex head cap screw (5), flat washers (6),and self-locking nut (4). Tighten self-locking nut.b.Install hex head cap screws (2), flatwashers (3), and self-locking nuts (1).Tighten self-locking nuts.NOTEFOLLOW-ON-TASK:Strikeoff extension assembly installed perTM 5-3895-373-10.END OF TASK15-151/(15-152 blank)