TM 5-3895-373-20
NOTE
This procedure applies to strikeoff
components on both the left and
right sides of the paving machine.
For this procedure, only the left side
strikeoff components are shown.
A.
REMOVE.
1.
REMOVE STRIKEOFF PLATE.
Cleaning solvent, P-D-680, is TOXIC
and flammable. Wear protective
goggles and gloves. Use only in a
well ventilated area. Avoid contact
with skin, eyes, and clothes, and do
not breathe vapors. Keep away from
heat or flame. Never smoke when
using solvent; the flashpoint for
Type m cleaning solvent is 200°F
(93,3°C). Failure to do so may result
in injury or death to personnel.
If personnel become dizzy while
using cleaning solvent, immediately
get fresh air and medical help. If
solvent contacts skin or clothes,
flush with cold water. If solvent
contacts eyes, flush eyes with water
and get immediate medical attention.
a.
Clean accumulated paving material from self-
locking nuts (1) using cleaning solvent and a
cleaning cloth. If necessary use a wire scratch
brush.
b.
Remove self-locking nuts (1) and flat washers
(2). Discard self-locking nuts.
c.
Remove strikeoff plate (3).
GO TO NEXT PAGE
15-103