Google+
Facebook
LinkedIn
Twitter
Digg
StumbleUpon
Home
Download PDF
Order CD-ROM
Order in Print
C. INSTALL - TM-5-3895-373-20_1100
15.10. REPLACE FLOW GATE COMPONENTS
TM-5-3895-373-20 Bituminous Distributor Body M918 Model D-63 Manual
Page Navigation
1088
1089
1090
1091
1092
1093
1094
1095
1096
1097
1098
TM 5-3895-373-20
C.
INSTALL - Continued.
WARNING
Thread locking compound can cause eye
damage. Wear safety goggles/glasses
when using. Avoid contact with eyes. If
compound contacts eyes, flush eyes with
water
and
get
immediate
medical
attention.
3.
APPLY THREAD LOCKING COMPOUND TO
THREADS OF HEX HEAD CAP SCREWS (7).
4.
INSTALL TEFLON FLAT WASHERS (9), HEMI
AUGER FLIGHTS (8), AND HEX HEAD CAP
SCREWS (7) ONTO AUGER SHAFT (5).
5.
INSTALL TEFLON FLAT WASHERS (6), HEMI
AUGER
FLIGHTS
(3),
QUARTER
AUGER
FLIGHTS (4),
LOCKWASHERS
(2), AND HEX
NUTS (1). TIGHTEN HEX NUTS TO 45 LB-FT
(61 N.m).
6.
START UP PAVING MACHINE, RAISE SCREED,
RETRACT EXTENSION SCREED, AND DRIVE
TRACTOR OFF OF CRIBBING BLOCKS PER TM
5-3895-373-10.
END OF TASK
15-71
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business