TM 5-3895-373-20
14.8.
REPLACE/REPAIR BLOWER MOTOR - Continued.
E.
INSTALL.
1.
INSTALL EXTENSION SCREED
BLOWER ASSEMBLIES AND FLEXIBLE
PIPE.
a.
Place blower assembly (25) onto
extension screed and connect flexible pipe
(26) to adapter (27).
b.
Place cushions (24) above and below
blower assembly (25) and install motor
mounting clamp (23).
c.
Install flat washer (21) onto hex head cap
screw (22).
Thread locking compound can cause
eye damage. Wear safety
goggles/glasses when using. Avoid
contact with eyes. If compound
contacts eyes, flush eyes with water
and get immediate medical attention.
d.
Apply thread locking compound to hex
head cap screws (22)
e.
Install hex head cap screws (22)
lockwashers (20), flat washers (21), and
hex nuts (19). Tighten hex nuts evenly
until motor is secure in cushions (24).
f.
Apply thread locking compound to threads
on clamps (18 and 29)
g.
Install clamps (18 and 29)
and hex nuts
(17 and 28). Tighten hex nuts evenly to 9
Ib-ft (12 Nm).
h.
Apply electrical insulating compound to
male end of blower electrical connector
(15)
i.
Connect screed harness electrical
connector (16) to blower electrical
connector (15).
GO TO NEXT PAGE
14-70