TM 5-3895-373-2014.8.REPLACE/REPAIR BLOWER MOTOR - Continued.E.INSTALL.1.INSTALL EXTENSION SCREEDBLOWER ASSEMBLIES AND FLEXIBLEPIPE.a.Place blower assembly (25) ontoextension screed and connect flexible pipe(26) to adapter (27).b.Place cushions (24) above and belowblower assembly (25) and install motormounting clamp (23).c.Install flat washer (21) onto hex head capscrew (22).Thread locking compound can causeeye damage. Wear safetygoggles/glasses when using. Avoidcontact with eyes. If compoundcontacts eyes, flush eyes with waterand get immediate medical attention.d.Apply thread locking compound to hexhead cap screws (22)e.Install hex head cap screws (22)lockwashers (20), flat washers (21), andhex nuts (19). Tighten hex nuts evenlyuntil motor is secure in cushions (24).f.Apply thread locking compound to threadson clamps (18 and 29)g.Install clamps (18 and 29)and hex nuts(17 and 28). Tighten hex nuts evenly to 9Ib-ft (12 N•m).h.Apply electrical insulating compound tomale end of blower electrical connector(15)i.Connect screed harness electricalconnector (16) to blower electricalconnector (15).GO TO NEXT PAGE14-70