TM 5-3895-373-20D.ASSEMBLE - Continued.3.INSTALL ADAPTER AND FLEXIBLE PIPEONTO BLOWER ASSEMBLY.a.Place adapter (31) onto blower assembly(35).Thread locking compound can causeeye damage. Wear safetygoggles/glasses when using. Avoidcontact with eyes. If compoundcontacts eyes, flush eyes with waterand get immediate medical attention.b.Apply thread locking compound to hexhead cap screws (34).c.Install adapter (31), hex head cap screws(34), lockwashers (33), and hex nuts (32).Tighten to 9 lb-ft (12 N•m).d.Place flexible pipe (30) onto adapter (31).GO TO NEXT PAGE14-69
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business