TM 5-3895-371-24 & P
(5)
Install vacu-flo lines (fig. 3-101) by loosely connecting pipe nuts (16), (8), and (12).
Loosely connecting pipe nuts (7) and (11), tighten pipe nuts (8) and (12); then securely tighten pipe
nuts (16), (7), and (11).
(6)
Install all covers shown in figure 3-102.
(7)
Install bushing (10, fig, 3-101) then place quadrant column on bushing and secure
assembly to the tank with two capscrews (1) and washers-
(8)
Install linkage (2) and secure with tapered pin (4) and cotter pin (3).
(9)
Connect cylinder linkage (14) to quadrant column and secure with cotter pin (15).
(10)
Install linkage assembly (9). Secure by tightening lockscrew (5) and installing C-clip
(6) and cotter pin (13).
(11)
Install hydraulic motor. (Refer to para 3-6.)
Section VII. REPAIR OF COMBUSTION CHAMBER
3-8. Combustion Chamber.
a.
Removal.
(1)
Remove low pressure burner assembly to gain access to combustion chamber compo-
nents. (Refer to para 2-39.)
(2)
Remove two capscrews (fig. 3-104), nuts and lockwashers that secure combustion
chamber components to the tank.
(3)
Remove the combustion block assembly, combustion tube and combustion tube holder.
b.
Inspection. Inspect combustion tube for cracks, holes, or crumbling condition. Replace if
defective.
c.
Installation.
into tank.
Assemble combustion block assembly, combustion tube, and combustion tube holder
(2)
Secure components with two capscrews, nuts and lockwasher.
(3)
Re-install tow pressure burner assembly. (Refer to para 2-39.)
3-86