TM 5-3895-371-24 & P
(c)
Remove hydraulic line (23) from hydraulic motor (19) and hydraulic drive motor
at blower (18).
(d)
Remove short hydraulic line from hydraulic drive blower motor to control valve.
b.
NOTE
Remove plugs as connections are made.
(1)
Install hydraulic line (23) to hydraulic drive motor at blower (18) and hydraulic motor
(19).
(2)
Install hydraulic line (13) at side of blower (18) with four bolts and washers thru pipe
flange block.
(3) Install hydraulic line (11) at right side of hydraulic motor (19) with four bolts and
washers thru pipe flange block.
(4) Route hydraulic lines (11) and (13) thru `U' holders (20) and (22) over frame cross rails
and down to hydraulic pump (10). Install new nylon ties around hydraulic lines to `U' holders.
(5)
Install hydraulic line (16) to 'T' on bottom of hydraulic motor (19); tighten fitting.
(6) Route hydraulic line (16) along inside of LH frame rail, thru hole in main cross brace
and down to hydraulic tank (4). Install new nylon ties around hydraulic line (16) to electrical harness
inside frame rail; space approximately every two feet.
(7)
Install and tighten hydraulic fitting (2) on hydraulic line (16) to bottom of hydraulic
tank (4).
(8) Install hydraulic lines (11) right side and (13) on left side of hydraulic pump (10) as
illustrated, with eight bolts and washers thru two pipe flange blocks (14).
(9) Install one end of hydraulic line (8) to bottom of hydraulic pump (10); tighten hy-
draulic fitting (9).
(10) Install other end of hydraulic line (8) to bottom of hydraulic tank (4) as illustrated;
tighten hydraulic fitting (1).
(11)
Install one end of hydraulic line (17) to oil filter (6), as illustrated; tighten hose clamp (7).
(12) Install other end of hydraulic line (17) to elbow on `T' at hydraulic tank (4); tighten
hose clamp (3).
(13) Install hydraulic line (15) to oil filter (6) and rear of hydraulic pump (10); tighten hose
clamps (5) and (12).
(14) Refill hydraulic tank (4) and test for leaks.
2-37