TM 5-3895-385-23-2
0292
Hydraulic Oil Charge Filter Hydraulic Hose Removal -- Continued.
CAUTION
Tag and label hydraulic hoses prior to removal. Hydraulic hoses must be installed correctly for
proper operation. Failure to comply may cause damage to equipment.
1. Disconnect hydraulic hose 22 (Figure 1, Item 3), hydraulic hose 23 (Figure 1, Item 2), and hydraulic hose 21
(Figure 1, Item 4) from hydraulic oil charge filter (Figure 1, Item 1).
2. Disconnect hydraulic hose 22 (Figure 1, Item 3) from propulsion pump (Figure 1, Item 7).
3. Disconnect hydraulic hose 23 (Figure 1, Item 2) from variable auger pump (Figure 1, Item 5).
4. Disconnect hydraulic hose 21 (Figure 1, Item 4) from variable charge pump (Figure 1, Item 6).
5. Cap/plug all hydraulic hose 22 (Figure 1, Item 3), hydraulic hose 23 (Figure 1, Item 2), and hydraulic hose 21
(Figure 1, Item 4) and hydraulic fittings.
END OF TASK
Hydraulic Oil Charge Filter Hydraulic Hose Inspection
1. Inspect hydraulic hoses (Figure 1, Items 2, 3, and 4) and fittings for cracks, holes, wear, or deformities.
Replace hydraulic hoses if damaged.
2. Inspect hydraulic fittings on filter, pumps, and hoses for cracks, stripped threading, wear, or deformities.
Replace component if damaged.
END OF TASK
Hydraulic Oil Charge Filter Hydraulic Hose Installation
1. Remove caps/plugs from all hydraulic hose 22 (Figure 1, Item 3), hydraulic hose 23 (Figure 1, Item 2), and
hydraulic hose 21 (Figure 1, Item 4) and hydraulic fittings.
2. Connect hydraulic hose 21 (Figure 1, Item 4) onto variable charge pump (Figure 1, Item 6).
3. Connect hydraulic hose 23 (Figure 1, Item 2) onto variable auger pump (Figure 1, Item 5).
4. Connect hydraulic hose 22 (Figure 1, Item 3) onto propulsion pump (Figure 1, Item 7).
5. Connect hydraulic hose 22 (Figure 1, Item 3), hydraulic hose 23 (Figure 1, Item 2), and hydraulic hose 21
(Figure 1, Item 4) onto hydraulic oil charge filter (Figure 1, Item 1).
END OF TASK
FOLLOW-ON TASK
2. Verify proper operation.
3. Dispose of hydraulic oil and wiping rags In Accordance With (IAW) local Standard Operating Procedure
(SOP).
END OF TASK
END OF WORK PACKAGE