TM 5-3895-385-23-1
FIELD MAINTENANCE
BITUMINOUS MATERIAL PAVING MACHINE (BMPM)
RIGHT CONTROL PEDESTAL DISPLAY MALFUNCTION
INITIAL SETUP:
Test Equipment
References -- Continued
WP 0373, Vol 2
Personnel Required
WP 0375, Vol 2
91L
WP 0386, Vol 2
Assistant
WP 0399, Vol 2
References
WP 0443, Vol 3
WP 0447, Vol 3
WP 0263, Vol 2
WP 0451, Vol 3
WP 0277, Vol 2
Equipment Conditions
Engine off (TM 5-3895-385-10)
TROUBLESHOOTING PROCEDURES
Table 1. Right Control Pedestal Display Malfunction Troubleshooting Procedures.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1. No power to display.
1. Turn keyless engine switch to
the AUX position (TM 5-3895-
385-10), but do not start engine
(TM 5-3895-385-10).
2. Check to see if the right control
1. If right control pedestal display
pedestal display displays
displays anything, turn keyless
anything.
engine switch to the OFF
position (TM 5-3895-385-10),
and proceed to malfunction 8.
2. If right control pedestal display
does not display anything,
proceed to next malfunction.
2. Fuse box malfunction.
3. Check to see if the left control
1. If left control pedestal display
pedestal display displays
displays anything, turn keyless
anything.
engine switch to the OFF
position (TM 5-3895-385-10),
and proceed to next malfunction.