• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
Table 1. Right Screed Horn Keypad Fault Troubleshooting Procedures -- Continued
Table 1. Right Screed Horn Keypad Fault Troubleshooting Procedures -- Continued

Field Maintenance Manual For Bituminous Material Paving Machine - 1 Page Navigation
  946    947    948    949    950  951  952    953    954    955    956  
img
TM 5-3895-385-23-1
0192
Table 1. Right Screed Horn Keypad Fault Troubleshooting Procedures -- Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
2. If no continuity is present,
replace damaged
communication cable (WP 0386,
Vol 2).
4. Measure for continuity (WP
1. If continuity is present, proceed
0443, Vol 3) from C1 J1 pin B to
to next test.
C1 J2 pin B (WP 0451, Vol 3,
Figure 51).
2. If no continuity is present,
replace damaged
communication cable (WP 0386,
Vol 2).
5. Measure for continuity (WP
1. If no continuity is present,
0443, Vol 3) from C1 J1 pin C to
replace damaged
C1 J2 pin C (WP 0451, Vol 3,
communication cable (WP 0386,
Figure 51).
Vol 2).
2. If continuity is present, proceed
to next malfunction.
9. Communication cable C1 has
1. Measure for continuity (WP
1. If continuity is present, replace
short circuit.
0443, Vol 3) from C1 J1 pin A to
damaged communication cable
every other pin on C1 J1 (WP
(WP 0386, Vol 2).
0451, Vol 3, Figure 51).
2. If no continuity is present,
proceed to next test.
2. Measure for continuity (WP
1. If continuity is present, replace
0443, Vol 3) from C1 J1 pin B to
damaged communication cable
every other pin on C1 J1 (WP
(WP 0386, Vol 2).
0451, Vol 3, Figure 51).
2. If no continuity is present,
proceed to next test.
3. Measure for continuity (WP
1. If continuity is present, replace
0443, Vol 3) from C1 J1 pin C to
damaged communication cable
every other pin on C1 J1 (WP
(WP 0386, Vol 2).
0451, Vol 3, Figure 51).
2. If no continuity is present,
proceed to next malfunction.
0192-8


Privacy Statement
Press Release
Contact

© Copyright Integrated Publishing, Inc.. All Rights Reserved.