Table 1. Right Slope Up Fault Troubleshooting Procedures -- Continued
LEFT SLOPE DOWN FAULT

Field Maintenance Manual For Bituminous Material Paving Machine - 1 Page Navigation
  517    518    519    520    521  522  523    524    525    526    527  
img
TM 5-3895-385-23-1
0120
Table 1. Right Slope Up Fault Troubleshooting Procedures -- Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
3. Screed controller (ECM) has
1. Disconnect main wiring harness
damage or loose pin.
W1 J1 from screed controller
module ECM (WP 0451, Vol 3,
Figure 1).
2. Check screed controller module
1. If screed controller module ECM
ECM for damage or loose pin.
has damage or loose pin,
replace screed controller module
ECM (WP 0399, Vol 2).
2. If no damage is found, proceed
to next malfunction.
4. Main wiring harness has an
Measure for continuity (WP 0443,
1. If no continuity is present,
open circuit.
Vol 3) between main wiring harness
replace main wiring harness
W1 J1 Pin 42 and main wiring
(WP 0373, Vol 2).
harness W1 J38 Pin 7 (WP 0451,
Vol 3, Figure 1).
2. If continuity is present, proceed
to next malfunction.
5. Main wiring harness has a short
Measure for continuity (WP 0443,
1. If continuity is present, replace
circuit.
Vol 3) between main wiring harness
main wiring harness (WP 0373,
W1 J1 Pin 42 and all other pins on
Vol 2).
the main wiring harness W1 J1 (WP
0451, Vol 3, Figure 1).
2. If no continuity is present,
replace screed controller module
ECM (WP 0399, Vol 2).
END OF WORK PACKAGE