RIGHT SLOPE UP FAULT
Table 1. Right Slope Up Fault Troubleshooting Procedures -- Continued

Field Maintenance Manual For Bituminous Material Paving Machine - 1 Page Navigation
  516    517    518    519    520  521  522    523    524    525    526  
img
TM 5-3895-385-23-1
0120
Table 1. Right Slope Up Fault Troubleshooting Procedures -- Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
3. Press right slope up key on
pedestal top (TM 5-3895-385-
10).
4. Measure voltage (WP 0443, Vol
1. If voltage reads a minimum of 22
3) between pin 1 and 2 on W10
Volts Direct Current (VDC),
J16 (WP 0451, Vol 3, Figure 27)
replace right slope hydraulic
while pressing right slope up key
solenoid (WP 0312, Vol 2).
on pedestal top.
2. If voltage reads below 22 VDC,
turn keyless engine switch to the
OFF position (TM 5-3895-385-
10), and proceed to next test.
5. Disconnect main wiring harness
W1 J38 from main manifold
wiring harness W10 J2 (WP
0451, Vol 3, Figure 27).
6. Turn keyless engine switch to
the AUX position. Do not start
engine (TM 5-3895-385-10).
7. Press right slope up key on
platform control (TM 5-3895-
385-10).
8. Measure voltage (WP 0443, Vol
1. If voltage reads a minimum of 22
3) from W1 J38 Pin 7 (WP 0451,
VDC, turn keyless engine switch
Vol 3, Figure 1) to a known good
to the OFF position (TM 5-3895-
ground while pressing right slope
385-10), and replace main
up key on platform control.
manifold wiring harness (WP
0376, Vol 2).
2. If voltage reads below 22 VDC,
turn keyless engine switch to the
OFF position (TM 5-3895-385-
10), and proceed to next
malfunction.