• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
Table 1. Left Slope Up Fault Troubleshooting Procedures -- Continued
RIGHT SLOPE UP FAULT

Field Maintenance Manual For Bituminous Material Paving Machine - 1 Page Navigation
  514    515    516    517    518  519  520    521    522    523    524  
img
TM 5-3895-385-23-1
0119
Table 1. Left Slope Up Fault Troubleshooting Procedures -- Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
3. Screed controller (Electronic
1. Disconnect main wiring harness
Control Module (ECM)) has
W1 J1 from screed controller
damage or loose pin.
module ECM (WP 0451, Vol 3,
Figure 1).
2. Check screed controller module
1. If screed controller module ECM
ECM for damage or loose pin.
has damage or loose pin,
replace screed controller module
ECM (WP 0399, Vol 2).
2. If no damage is found, proceed
to next malfunction.
4. Main wiring harness has an
Measure for continuity (WP 0443,
1. If continuity is present, proceed
open circuit.
Vol 2) between main wiring harness
to next malfunction.
W1 J1 Pin 33 and main wiring
harness W1 J38 Pin 1 (WP 0451,
Vol 3, Figure 1).
2. If no continuity is present,
replace main wiring harness
(WP 0373, Vol 2).
5. Main wiring harness has a short
Measure for continuity (WP 0443,
1. If continuity is present, replace
circuit.
Vol 2) between main wiring harness
main wiring harness (WP 0373,
W1 J1 Pin 33 and all other pins on
Vol 2).
the main wiring harness W1 J1 (WP
0451, Vol 3, Figure 1).
2. If no continuity is present,
replace screed controller module
ECM (WP 0399, Vol 2).
END OF WORK PACKAGE
0119-3/4 blank


Privacy Statement
Press Release
Contact

© Copyright Integrated Publishing, Inc.. All Rights Reserved.