TM 5-3895-385-23-1
0114
Table 1. Right Screed Slope Fails to Lower Troubleshooting Procedures -- Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
2. If pressure reads below 1800 psi
(12,410 kPa), turn keyless
engine switch to the OFF
position (TM 5-3895-385-10),
1. Attempt manual override test of
1. If test is successful (right screed
right screed slope lower
slope lowers), turn keyless
engine switch to the OFF
manifold (WP 0312, Vol 2).
position (TM 5-3895-385-10),
and replace right screed slope
lower hydraulic solenoid (WP
0312, Vol 2).
2. If test fails, turn keyless engine
switch to the OFF position (TM
5-3895-385-10), and proceed to
next test.
2. Attach hydraulic pressure tester
(WP 0442, Vol 3) to hydraulic
pressure at hydraulic connection
point RSB on the main hydraulic
manifold (WP 0441, Vol 3).
3. Start BMPM engine (TM 5-3895-
385-10).
4. Check hydraulic pressure at
1. If hydraulic pressure reads a
hydraulic connection point RSB
minimum of 1800 psi (12,410
on the main hydraulic manifold
kPa), turn keyless engine switch
(WP 0441, Vol 3) while pressing
to the OFF position (TM 5-3895-
right screed slope lower key on
385-10), and proceed to next
screed control (TM 5-3895-385-
malfunction.
10).
2. If pressure reads below 1800 psi
(12,410 kPa), turn keyless
engine switch to the OFF
position (TM 5-3895-385-10),
and replace right screed slope
lower hydraulic solenoid (WP
0312, Vol 2).
6. Loss of hydraulic pressure.
1. Attach hydraulic pressure tester
(WP 0442, Vol 3) to hydraulic
hose 95B at right screed slope
hydraulic cylinder (WP 0285, Vol
2).
0114-3