Table 1. Hopper Out Fault Troubleshooting Procedures -- Continued
HOPPER IN FAULT

Field Maintenance Manual For Bituminous Material Paving Machine - 1 Page Navigation
  464    465    466    467    468  469  470    471    472    473    474  
img
TM 5-3895-385-23-1
0104
Table 1. Hopper Out Fault Troubleshooting Procedures -- Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
4. Main wiring harness has an
1. Measure for continuity (WP
1. If continuity is present, proceed
open circuit.
0443, Vol 3) between main
to next malfunction.
wiring harness W1 J3 Pin 9 and
main wiring harness W1 J8 Pin 2
(WP 0451, Vol 3, Figure 1).
2. If no continuity is present,
replace main wiring harness
(WP 0373, Vol 2).
5. Main wiring harness has a short
1. Measure for continuity (WP
1. If continuity is present, replace
circuit.
0443, Vol 3) between main
main wiring harness (WP 0373,
wiring harness W1 J3 Pin 9 and
Vol 2).
all other pins on the main wiring
harness W1 J3 (WP 0451, Vol 3,
Figure 1).
2. If no continuity is present,
replace output module ECM (WP
0399, Vol 2).
END OF WORK PACKAGE