• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
Table 1. SPN#1080, FMI#3 ? High Voltage at Sensor Supply Circuit Number 2 -- Continued
Table 1. SPN#1322, FMI#31 - Engine Misfire Multiple Cylinders -- Condition Exists -- Continued

Field Maintenance Manual For Bituminous Material Paving Machine - 1 Page Navigation
  326    327    328    329    330  331  332    333    334    335    336  
img
. . .
TM 5-3895-385-23-1
0071
FIELD MAINTENANCE
BITUMINOUS MATERIAL PAVING MACHINE (BMPM)
SPN#1322, FMI#31 ― ENGINE MISFIRE FOR MULTIPLE CYLINDERS -- CONDITION EXISTS
INITIAL SETUP:
Personnel Required
References -- Continued
91L
WP 0337, Vol 2
References
WP 0338, Vol 2
WP 0085
WP 0357, Vol 2
WP 0277, Vol 2
Equipment Conditions
WP 0327, Vol 2
Engine off (TM 5-3895-385-10)
Engine hood assembly removed (WP 0433, Vol 2)
TROUBLESHOOTING PROCEDURES
Table 1. SPN#1322, FMI#31 ― Engine Misfire Multiple Cylinders -- Condition Exists.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1. Fault in the fuel system.
1. Install fuse box (WP 0277, Vol
2).
2. Connect battery cables (WP
0357, Vol 2).
3. Turn keyless engine switch to
the AUX position (TM 5-3895-
385-10), but do not start engine.
Wait 30 seconds.
4. Check active engine faults
1. If fault codes other than
screen for multiple fault codes
SPN#1322, FMI#31 are
other than SPN#1322, FMI#31.
displayed, turn keyless engine
switch to the OFF position (TM
5-3895-385-10), and
troubleshoot fault codes.
2. If fault codes other than
SPN#1322, FMI#31 are not
displayed, proceed to next test.
0071-1