Table 1. SPN#645, FMI#5 ? High Resistance or No Current at Number Four Injector DRIVER or RETURN Pin - Continued
SPN#651, FMI#5 ? HIGH RESISTANCE OR NO CURRENT AT NUMBER ONE INJECTOR DRIVER OR RETURN PIN

Field Maintenance Manual For Bituminous Material Paving Machine - 1 Page Navigation
  252    253    254    255    256  257  258    259    260    261    262  
img
TM 5-3895-385-23-1
0057
Table 1. SPN#645, FMI#5 ― High Resistance or No Current at Number Four Injector
DRIVER or RETURN Pin -- Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
2. If no damage found, restore
equipment to original condition,
and proceed to next
malfunction.
19.Multiple errors displayed.
1. Start engine and run at idle for
1 minute (TM 5-3895-385-10).
2. Check active engine faults
1. If fault code(s) SPN#645,
screen for fault code(s)
FMI#5; SPN#653, FMI# 5; or
SPN#645, FMI#5; SPN#653,
SPN#652, FMI#5 is displayed,
FMI# 5; or SPN#652, FMI#5.
turn keyless engine switch to
OFF position (TM 5-3895-385-
10), and replace ECM (WP
0332, Vol 2).
2. If fault code(s) SPN#645,
FMI#5; SPN#653, FMI# 5; or
SPN#652, FMI#5 is not
displayed, turn keyless engine
switch to OFF position (TM 5-
3895-385-10). No fault present;
restore equipment to original
condition.
END OF WORK PACKAGE
0057-12