TM 5-3895-385-10
0019
Fill Hydraulic Fluid Reservoir -- Continued.
WARNING
Do not loosen or remove the reservoir cap when the hydraulic fluid is hot. Failure to comply may
cause injury or death to personnel.
CAUTION
Reservoir cap is under spring pressure. Use care when removing reservoir cap not to lose
components. Failure to comply may cause damage to equipment.
Do not allow contaminants to enter hydraulic system. Area around reservoir cap must be
cleaned before removing reservoir cap. Failure to comply may cause damage to equipment.
3. Apply firm downward pressure to top of reservoir cap (Figure 3, Item 1), and remove three wing nuts (Figure
3, Item 2), flat washers (Figure 3, Item 3), and reservoir cap from threaded studs (Figure 3, Item 6).
4. Remove spring (Figure 3, Item 5) and O-ring (Figure 3, Item 4) from filler neck (Figure 3, Item 7).