TM 5-3895-385-10
0006
INSTALLING SONIC AUGER SENSOR
Figure 12. Sonic Auger Sensor Mount.
NOTE
Sonic auger sensors are used to control conveyor and auger speed when set to automatic.
These sensors will need to be installed by the operator before use.
The procedure for installation and removal of the sonic auger sensor is the same whether
being performed on the left side or right side. Left side shown.
1. Obtain sonic auger sensor from BMPM toolbox.
2. Insert thin end of sonic auger sensor (Figure 12, Item 1) into sonic auger sensor mount (Figure 12, Item 2) on
end gate (Figure 12, Item 7).
3. Ensure corded side of sonic auger sensor (Figure 12, Item 1) is facing front (toward the hopper).
4. Tighten wing screw (Figure 12, Item 3) to secure sonic auger sensor (Figure 12, Item 1) into sonic auger
sensor mount (Figure 12, Item 2).
5. Remove cap (Figure 12, Item 5) from socket (Figure 12, Item 6) on BMPM.
6. Remove cap (Figure 12, Item 7) from sonic auger connector (Figure 12, Item 4) on sonic auger sensor.
7. Install sonic auger connector (Figure 12, Item 4) into socket (Figure 12, Item 6).
END OF TASK