TM 5-3895-385-10
0004
Left Screed Control Auger/Conveyor Controls -- Continued.
Table 19. Left Screed Control Auger/Conveyor Keypad -- Continued.
KEY
CONTROL/INDICATOR
FUNCTION
4
Left Conveyor Speed Up
Pressing and holding key will cause left conveyor to increase in speed.
LEDs are used in conjunction with left conveyor speed down key LEDs
(Figure 19, Item 5). The number of total illuminated LEDs across both
keys indicates speed (more LEDs illuminated indicates higher speed).
5
Left Conveyor Speed Down
Pressing and holding key will cause left conveyor to decrease in speed.
LEDs are used in conjunction with left conveyor speed up key LEDs
(Figure 19, Item 4). The number of total illuminated LEDs across both
keys indicates speed (more LEDs illuminated indicates higher speed).
6
Left Extension Retract
Pressing and holding key will cause left screed extension to retract.
Releasing key will maintain extension position.
Top LED will be illuminated when function is active.
7
Left Extension Extend
Pressing and holding key will cause left screed extension to extend.
Releasing key will maintain extension position.
Top LED will be illuminated when function is active.
Pressing and holding key will lower left screed extension to slope down
8
Left Screed Extension Slope
(more angle).
Down
Releasing key will hold extension in position.
Top LED will be illuminated when function is active.
9
Left Screed Extension Slope
Pressing and holding key will raise left screed extension to slope back
Up
toward level (less angle).
Releasing key will hold extension in position.
Top LED will be illuminated when function is active.
When left auger/conveyor manual mode is selected, pressing and
10
Left Material Pile Height
holding this key reduces the speed of the left auger and conveyor.
Auger/Conveyor Speed
minus (-)
When left auger/conveyor automatic mode is selected, pressing and
holding this key decreases the left material pile height controlled with
the use of the sonic auger sensors.
Number of illuminated LEDs and frequency of flashing indicates pile
height in automatic or auger/conveyor speed in manual. (More LEDs
illuminated and/or faster flashing indicates higher value.)
11
Left Conveyor Bypass
Pressing key will turn off left conveyor.
Top LED will be illuminated when left conveyor bypass is active (left
conveyor will be off). Pressing key again will turn off bypass and turn off
LED (conveyor will resume function).
0004-31