TM 5-3895-373-34
2.55
REPLACE VALVE PANEL CONTROL VALVES AND FLOW DIVIDERS - Continued.
C.
INSTALL - Continued.
Hydraulic fitting sealant can cause eye
damage or skin irritation. Wash after
skin
contact.
Wear
safety
goggles/glasses when using. Avoid
contact with eyes or skin. If sealant
contacts eyes, flush eyes with water and
get immediate medical attention.
I.
Apply hydraulic fitting sealant to exposed threads
on elbows (7, 8, 12, 13, 17, and 21) and straight
adapters (15 and 19).
m.
Connect tube (20) to elbow (21). Tighten tube.
n.
Connect hoses (5 and 6) to elbows (7 and 8).
Tighten hoses.
o.
Connect tubes (16 and 18) to elbow (17) and
straight adapter (19) on bottom of return
manifold (9). Tighten tubes.
p.
Connect tubes (10 and 11) to elbows (12 and
13) on top of return manifold (9). Tighten tubes.
q.
Connect tube (14) to straight adapter (15) at end
of return manifold (9). Tighten tube.
GO TO NEXT PAGE
2-788