Table 2-7. Auger/Conveyor System Troubleshooting - Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1.
AUGER/CONVEYOR DOES NOT OPERATE OR OPERATES SLUGGISHLY- Continued.
WARNING
Hydraulic oil can be moderately flammable and can be an irritant to skin, eyes, and respiratory system.
Avoid prolonged exposure. Eye protection and rubber gloves must be worn when working with
hydraulic oil.
Step 5.
Install hydraulic system tester at inlet (3) for flow test per TM 9-4940-468-14. Check maximum flow
rate at manual auger/conveyor speed control valve inlet (3). Flow rate should be at least 7.9 gpm
(30 l/min). Refer to illustration.
If flow rate is at least 7.9 gpm (30 l/min), replace manual auger/conveyor speed control valve per
paragraph 2.55 and repair per paragraph 2.48.
2-49