TM 5-3895-373-34
2.50
REPAIR TOW POINT FLOW CONTROL VALVE - Continued.
D.
ASSEMBLE - Continued.
4.
INSTALL FITTINGS ONTO TOW POINT FLOW
CONTROL VALVE.
a.
Use cleaning cloth to wipe residue from threads
of all fittings.
WARNING
Pipe sealant can cause eye damage
or skin irritation. Wash after skin
contact. Wear safety goggles/glasses
when using. Avoid contact with eyes
or skin. If sealant contacts eyes,
flush
eyes
with
water
and
get
immediate medical attention.
b.
Apply pipe sealant to pipe threads of straight
adapters (3 and 4) and male threads of pipe
bushing (5). Install and tighten straight adapters
and pipe bushing.
c.
Apply pipe sealant to only one end of elbow (1).
Install treated side of elbow into pipe bushing (5).
Position elbow to face toward bottom of tow point
flow control valve (28). Tighten elbow.
d.
Apply pipe sealant to exposed threads of elbow
(1).
e.
Install pipe coupling (2) onto elbow (1). Tighten
pipe coupling.
NOTE
FOLLOW-ON-TASK:
Install tow point flow control valve on valve panel
per paragraph 2.55.
END OF TASK
2-682