TM 5-3895-373-34
B.
REPAIR - Continued.
Thread locking compound can cause eye
damage. Wear safety goggles/glasses when
using.
Avoid
contact
with
eyes.
If
compound contacts eyes, flush eyes with
water and get immediate medical attention.
g.
Apply thread locking compound to threads
of valve cartridge (8).
h.
Install hex nut (6) onto valve cartridge (8).
The countered bored end of the hex nut
goes against solenoid coil (7). Tighten to 5
lb-ft (7 Nm).
C.
INSTALL.
1.
INSTALL
FITTINGS
ONTO
SCREED
VIBRATION SOLENOID VALVE.
a.
Use cleaning cloth to wipe residue from
threads of pipe nipple (2) and tees (4 and
5).
Pipe sealant can cause eye damage or skin
irritation. Wash after skin contact. Wear
safety goggles/glasses when using. Avoid
contact with eyes or skin. If sealant contacts
eyes,
flush
eyes
with
water
and
get
immediate medical attention.
b.
Apply pipe sealant to threads on one end of
pipe nipple (2). Install pipe nipple into the
rear port, port stamped 1, of screed
vibration solenoid valve (1). Tighten pipe
nipple.
c.
Apply pipe sealant to pipe threads of tee
(5). Install tee so that when tightened, tee
points to the right when viewed from the
pipe nipple end of the screed vibration
solenoid valve. Refer to illustration.
Tighten tee.
d.
Apply pipe sealant to pipe thread ends of
tee (4). Install tee so that when tightened,
tee is at a right angle to valve body. Refer
to illustration. Tighten tee.
GO TO NEXT PAGE
2-647