TM 5-3895-373-34
C.
CLEAN - Continued.
Compressed
air
used
for
cleaning
purposes will not exceed 30 psi (207
kPa). Use only with effective chip
guarding
and
personal
protective
equipment
(goggles/face
shield
and
gloves).
Failure
to
take
proper
precautions may result in severe injury
or loss of vision.
b.
Use 30 psi (207 kPa) maximum compressed
air to remove any foreign matter from valve
body, threaded surfaces, bores, and seal
grooves.
c.
Dry all parts with a clean, lint-free cloth.
Thread locking compound solvent can
cause eye damage. Wear safety
goggles/glasses when using. Avoid
contact with eyes. If solvent contacts
eyes, flush eyes with water and get
immediate medical attention.
d.
Use a culture swab soaked in thread locking
compound solvent to clean thread locking
compound residue from valve body.
2.
CLEAN BOLTS TREATED WITH THREAD
LOCKING COMPOUND.
a.
Clean threads of valve mounting bolts and
valve bracket bolts with thread locking
compound solvent.
b.
Dry bolts with a cleaning cloth.