TM 5-3895-373-34
D.
REPAIR - Continued.
d.
Place balancer unit frame (94) on hydraulic
press frame, with rear of frame facing up.
e.
Use a mandrel (Item 11, Appendix C) to
press new sleeve bushings (175) into
balancer unit frame (94), at the same time
pressing out old sleeve bushings.
f.
Sleeve bushings (175) must be 0.128 to
0.130 in. (3,25 to 3,30 mm) below
machined face of balancer unit frame when
installed.
g.
Turn balancer unit frame (94) over so front
end is facing up.
h.
Use a mandrel (Item 12, Appendix C) to
press new needle bearing (176) into front
end of balancer unit frame (94), at the
same time pressing out old needle bearing.
Discard needle bearing.
i.
Needle bearing (176) must be 0.098 to
0.118 in. (2,5 to 3,0 mm) below front face
of balancer frame (94) when installed.