TM 5-3895-373-34
2.16
ENGINE REPLACEMENT - Continued.
C.
INSTALL - Continued.
Hydraulic fitting sealant can cause
eye damage or skin irritation. Wash
after skin contact. Wear safety
goggles/glasses when using. Avoid
contact with eyes or skin. If sealant
contacts eyes, flush eyes with water
and get immediate medical attention.
c.
Coat threads of straight adapters (132 and 133)
with hydraulic fitting sealant and install outlet
hoses (130 and 131) onto left auxiliary pump
(128).
d.
Coat threads of intake straight adapter (129) and
hydraulic reservoir adapter, port #8A, with
hydraulic fitting sealant. Using combination
wrench (Item 115, Appendix D), install suction
hose (127) onto left auxiliary pump (128) and on
hydraulic reservoir adapter #8A.
GO TO NEXT PAGE
2-132