TM 5-3895-373-34
C.
INSTALL - Continued.
9.
RECONNECT HYDRAULIC HOSES (144 AND 146)
TO AUXILIARY VIBRATION PUMP.
Hydraulic fitting sealant can cause
eye damage or skin irritation. Wash
after skin contact. Wear safety
goggles/glasses when using. Avoid
contact with eyes or skin. If sealant
contacts eyes, flush eyes with water
and get immediate medical attention.
a.
Coat threads of straight adapter (145) and elbow
(147) with hydraulic fitting sealant.
b.
Install outlet hoses (144 and 146) on auxiliary
vibration pump (141).
10.
RECONNECT HYDRAULIC HOSES TO LEFT AND
RIGHT AUXILIARY PUMPS.
a.
Coat threads of straight adapters (139 and 140)
with hydraulic fitting sealant and install outlet
hoses (137 and 138) onto right auxiliary pump
(135).
b.
Coat threads of intake elbow (136) and hydraulic
reservoir elbow, port #9 with hydraulic fitting
sealant. ing combination wrench (Item 116,
Appendix D) install suction hose (134) onto right
auxiliary pump (135) and hydraulic reservoir
elbow, port #9.