TM 5-3895-373-20
7.21.
REPAIR ELECTRICAL HARNESSES - Continued.
C.
INSTALL.
WARNING
When connecting batteries, connect
positive
battery
cable
before
connecting negative battery cable.
Failure to connect batteries in the
proper
sequence
may
lead
to
electrical shock or short circuit and
result in personnel injury.
1.
RECONNECT POSITIVE BATTERY CABLE (6)
AND
BATTERY
NUT
(4)
TO
POSITIVE
TERMINAL OF INBOARD BATTERY.
2.
RECONNECT NEGATIVE BATTERY CABLE
(5) AND BATTERY NUT (4) TO NEGATIVE
TERMINAL OF OUTBOARD BATTERY.
WARNING
Electrical insulating varnish fumes
can be harmful if inhaled. Use only in
a
well
ventilated
area.
Avoid
prolonged exposure to fumes. If
personnel become dizzy or drowsy
during use, get immediate medical
attention.
3.
APPLY ELECTRICAL INSULATING VARNISH
TO BATTERY TERMINALS.
4.
INSTALL BATTERY TERMINAL COVERS (3)
ONTO BATTERY TERMINALS.
5.
INSTALL BATTERY BOX COVERS (2) AND
BUCKLE
BATTERY
BOX
HOLDDOWN
STRAPS (1).
NOTE
FOLLOW-ON-TASKS:
Close rear top left access door per TM 5-3895-373-10.
Install left access cover per TM 5-3895-373-10.
NOTE
Close other access door(s) and install access cover(s) removed during this procedure. Refer to
paragraph 2.22 and to TM 5-3895-373-10.
END OF TASK
7-168