TM 5-3895-373-20
B.
CLEAN - Continued.
Cleaning solvent, PD680, is TOXIC
and flammable. Wear protective
goggles and gloves. Use only in a
well ventilated area. Avoid contact
with skin, eyes, and clothes, and do
not breathe vapors. Keep away from
heat or flame. Never smoke when
using solvent; the flash point for
Type III cleaning solvent is 200°F
(93,30C). Failure to do so may result
in injury or death to personnel.
If personnel become dizzy while
using cleaning solvent, immediately
get fresh air and medical help. If
solvent contacts skin or clothes,
flush with cold water. If solvent
contacts eyes, flush eyes with water
and get immediate medical attention.
2.
USE
A
CLEANING
CLOTH
AND
CLEANING SOLVENT TO WIPE OFF
MANIFOLD MOUNTING SURFACE ON
ENGINE BLOCK.
C.
INSTALL.
1.
INSTALL INTAKE MANIFOLD.
a.
Install intake manifold (8) and gaskets (9,
10, and 11) using hex head cap screws (5
and 6) and washers (7).
b.
Tighten hex head cap screws (5 and 6) to
37 lbft (50 N.m).
GO TO NEXT PAGE
3-21