TM 5-3895-373-20B.CLEAN - Continued.Cleaning solvent, PD680, is TOXICand flammable. Wear protectivegoggles and gloves. Use only in awell ventilated area. Avoid contactwith skin, eyes, and clothes, and donot breathe vapors. Keep away fromheat or flame. Never smoke whenusing solvent; the flash point forType III cleaning solvent is 200°F(93,30C). Failure to do so may resultin injury or death to personnel.If personnel become dizzy whileusing cleaning solvent, immediatelyget fresh air and medical help. Ifsolvent contacts skin or clothes,flush with cold water. If solventcontacts eyes, flush eyes with waterand get immediate medical attention.2.USE A CLEANING CLOTH ANDCLEANING SOLVENT TO WIPE OFFMANIFOLD MOUNTING SURFACE ONENGINE BLOCK.C.INSTALL.1.INSTALL INTAKE MANIFOLD.a.Install intake manifold (8) and gaskets (9,10, and 11) using hex head cap screws (5and 6) and washers (7).b.Tighten hex head cap screws (5 and 6) to37 lbft (50 N.m).GO TO NEXT PAGE3-21