TM 5-3895-373-20C.INSTALL - Continued.j.Install mounting panel (60) and secure withtapping screws (56), leaving one screw out toallow for connection of ground wires.k.Apply electrical insulating compound to insideterminals of electrical connector (59) andconnect to valve harness.Electrical insulating varnish fumescan be harmful if inhaled. Use only ina well ventilated area. Avoidprolonged exposure to fumes. Ifpersonnel become dizzy or drowsyduring use, get immediate medicalattention.I.Install ground wires 17 (57) and G201 (58) andremaining tapping screw (56). Apply electricalinsulating varnish to wires and screw.m. Install buss bar mounting bracket (53). Securewith flat washers (52) and machine screws (51).n.Install circuit breakers (55), buss bar (54), andwires. Refer to wiring diagram. Secure buss barand wires with self-locking nuts (50). Applyelectrical insulating varnish to wire terminals.GO TO NEXT PAGE15-13