TM 5-3895-373-20C.INSTALL - Continued.Thread locking compound can causeeye damage. Wear safetygoggles/glasses when using. Avoidcontact with eyes. If compoundcontacts eyes, flush eyes with waterand get immediate medical attention.f.Install lockwashers (11) onto bolts (10)and apply thread locking compound tothreads of bolts.g.Install manifold (12) using bolts (10).Tighten bolts to 9 lb-ft (12 N•m).h.Use cleaning cloth to wipe residue fromthreads of straight adapters (23 and 24).Hydraulic fitting sealant can causeeye damage or skin irritation. Washafter skin contact. Wear safetygoggles/glasses when using. Avoidcontact with eyes or skin. If sealantcontacts eyes, flush eyes with waterand get immediate medical attention.i.Apply hydraulic fitting sealant to threads ofstraight adapters (23 and 24).j.Connect fuel hoses (8 and 9).k.Apply hydraulic fitting sealant to threads ofstraight adapters (15 and 17). Connectfuel hoses (7) to adapters.GO TO NEXT PAGE14-55