TM 5-3895-373-20
C.
INSTALL - Continued.
Thread locking compound can cause
eye damage. Wear safety
goggles/glasses when using. Avoid
contact with eyes. If compound
contacts eyes, flush eyes with water
and get immediate medical attention.
f.
Install lockwashers (11) onto bolts (10)
and apply thread locking compound to
threads of bolts.
g.
Install manifold (12) using bolts (10).
Tighten bolts to 9 lb-ft (12 Nm).
h.
Use cleaning cloth to wipe residue from
threads of straight adapters (23 and 24).
Hydraulic fitting sealant can cause
eye damage or skin irritation. Wash
after skin contact. Wear safety
goggles/glasses when using. Avoid
contact with eyes or skin. If sealant
contacts eyes, flush eyes with water
and get immediate medical attention.
i.
Apply hydraulic fitting sealant to threads of
straight adapters (23 and 24).
j.
Connect fuel hoses (8 and 9).
k.
Apply hydraulic fitting sealant to threads of
straight adapters (15 and 17). Connect
fuel hoses (7) to adapters.
GO TO NEXT PAGE
14-55